MAINTENANCE AND CARE
A minimal amount of care can keep your
battery charger working properly for years.
• Clean the clamps each time you are
nished charging. Wipe off any battery uid
that may have come in contact with the
clamps to prevent corrosion.
• Occasionally cleaning the case of the
charger with a soft cloth will keep the nish
shiny and help prevent corrosion.
• Coil the input and output cords neatly when
storing the charger. This will help prevent
accidental damage to the cords and charger.
• Store the charger unplugged from the AC
power outlet in an upright position.
• Store inside, in a cool, dry place. Do not
store the clamps on the handle, clipped
together, on or around metal, or clipped to
the cables.
TROUBLESHOOTING AND ERROR CODES
Error Codes
ERROR
CODE
DESCRIPTION REASON/SOLUTION
F01
The battery voltage is still under 10V
(for a 12V battery) or 5V (for a 6V
battery) after 2 hours of charging.
The battery could be bad. Have it checked or replaced.
F02
The charger cannot desulfate the
battery.
The battery could not be desulfated; have it checked or
replaced.
F03
The battery was unable to reach the
“full charge” voltage.
May be caused by trying to charge a large battery or bank of
batteries on too low of a current setting. Try again with a higher
current setting or have the battery checked or replaced.
F04
The connections to the battery are
reversed.
The battery is connected backwards. Unplug the charger and
reverse the connections to the battery.
F05
The charger was unable to keep
the battery fully charged in maintain
mode.
The battery won’t hold a charge. May be caused by a drain on
the battery or the battery could be bad. Make sure there are
no loads on the battery. If there are remove them. If there are
none, have the battery checked or replaced.
F06
The charger detected that the battery
may be getting too hot (thermal
runaway).
The charger automatically shuts the current off if it detects
the battery may be getting too hot. Have the battery
checked or replaced.
If you get an error code, check the connections and settings and/or replace the battery.
Troubleshooting
PROBLEM POSSIBLE CAUSE REASON/SOLUTION
Charger will not turn
on when properly
connected.
AC outlet is dead.
Poor electrical connection.
Battery is defective.
Check for open fuse or circuit
breaker supplying AC outlet.
Check power cord and extension
cord for loose tting plug.
Have the battery checked.
Three LEDs come on for
2 seconds, then turn off.
The charger is plugged into an
AC outlet.
No problem; this is normal.
Engine start does
not work.
Drawing more than 200 amps.
Failure to wait 3 minutes (180
seconds) between cranks.
The charger may be
overheated.
Battery may be severely
discharged.
Crank time varies with the amount
of current drawn. If cranking
draws more than 200 amps, crank
time may be less than 5 seconds.
When the Engine Start LED
blinks, wait 3 minutes of rest
time before the next crank.
The thermal protector may have
tripped and needs a little longer to
reset. Make sure the charger vents
are not blocked. Wait and try again.
On a severely discharged battery,
use the Boost rate for 10 to 15
minutes, to help assist in cranking.